Model # | - | Cold Climate Zone 59 °F 60%RH | Mild Climate Zone 77 °F 60%RH | Hot Climate Zone 104°F 100%RH | Dimensions (in) (LxWxH) | price |
---|---|---|---|---|---|---|
CSO-40 | Max Oil Absorption (lbs) | 1.63 | 1.43 | 0.82 | 4.2x3.2x19.1 | |
CSO-40 | Max FAD (scfm) | 45 | 40 | 20 | 4.2x3.2x19.1 | |
CSO-40 | Max Condensate Flow (GPH) | 0.15 | 0.24 | 0.51 | 4.2x3.2x19.1 | |
CSO-80 | Max Oil Absorption (lbs) | 3.4 | 3 | 1.7 | 4.2x3.2x32.2 | |
CSO-80 | Max FAD (scfm) | 90 | 80 | 40 | 4.2x3.2x32.2 | |
CSO-80 | Max Condensate Flow (GPH) | 0.32 | 0.5 | 1.1 | 4.2x3.2x32.2 | |
CSO-150 | Max Oil Absorption (lbs) | 6.4 | 5.4 | 2.8 | 9.6x16.2x16.4 | |
CSO-150 | Max FAD (scfm) | 170 | 150 | 75 | 9.6x16.2x16.4 | |
CSO-150 | Max Condensate Flow (GPH) | 0.61 | 0.9 | 1.7 | 9.6x16.2x16.4 | |
CSO-300 | Max Oil Absorption (lbs) | 13.3 | 11.2 | 5.7 | 13.6x26.8x28.8 | |
CSO-300 | Max FAD (scfm) | 350 | 300 | 150 | 13.6x26.8x28.8 | |
CSO-300 | Max Condensate Flow (GPH) | 0.51 | 1.9 | 3.5 | 13.6x26.8x28.8 | |
CSO-725 | Max Oil Absorption (lbs) | 32.3 | 27.1 | 13.8 | 14.5x37.1x32.3 | |
CSO-725 | Max FAD (scfm) | 850 | 725 | 362 | 14.5x37.1x32.3 | |
CSO-725 | Max Condensate Flow (GPH) | 2.6 | 4.6 | 8.5 | 14.5x37.1x32.3 | |
CSO-1250 | Max Oil Absorption (lbs) | 56 | 47 | 23.8 | 15.2x44.8x37.8 | |
CSO-1250 | Max FAD (scfm) | 1500 | 1250 | 625 | 15.2x44.8x37.8 | |
CSO-1250 | Max Condensate Flow (GPH) | 5.3 | 7.9 | 14.7 | 15.2x44.8x37.8 |
CSO Models 40CFM – 80CFM Mountable and Compact Oil Water Condensate Separation
Cyclonic Depressurization Chamber
The push-to-connect inlet and discharge ports allow for simple installation.
Stage 1: Absorption
The filter cartridge is filled with a polypropylene absorption material that removes the oil content out of the oil/water mixture.
Stage 2: Final Decontamination
The carbon pellets contained in the bottom of the cartridge do a final purification of the water before discharge to the environment.
CSO Models 150CFM – 1250CFM
Developed for Larger Air Compressors and High Quantities of Oil & Condensate Separation
Stage 1
Inlets for Condensate (Oil & Water) and Air
Stage 2
Oil Filter Cartridge (polypropylene fibers)
Stage 3
Activated carbon fiber cartridge (final oil elimination)
Stage 4
Clean Water Outlet (Residual Oil Content <10ppm)
Ventilation Filter
Provides ventilation for the system and eliminates condensate splashing.